Review




Structured Review

Taigen Bioscience labturbo virus mini kit (cat. no. lvn480-300)
Limit of Detection of <t> LabTurbo </t> TM AIO COVID-19 RNA Testing Kit for N1 and E Using the Rotor-Gene-Q Real-Time PCR Instrument
Labturbo Virus Mini Kit (Cat. No. Lvn480 300), supplied by Taigen Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labturbo+virus+mini+kit/labturbo+virus+mini+kit++cat++no++lvn480+300+/pmc08882663-110-29-44
Average 90 stars, based on 1 article reviews
labturbo virus mini kit (cat. no. lvn480-300) - by Bioz Stars, 2026-11
90/100 stars

Images

1) Product Images from "Clinical Comparative Evaluation of the LabTurbo TM AIO ® Reverse Transcription-Polymerase Chain Reaction and World Health Organization-Recommended Assays for the Detection of Emerging SARS-CoV-2 Variants of Concern"

Article Title: Clinical Comparative Evaluation of the LabTurbo TM AIO ® Reverse Transcription-Polymerase Chain Reaction and World Health Organization-Recommended Assays for the Detection of Emerging SARS-CoV-2 Variants of Concern

Journal: Infection and Drug Resistance

doi: 10.2147/IDR.S349669

Limit of Detection of  LabTurbo  TM AIO COVID-19 RNA Testing Kit for N1 and E Using the Rotor-Gene-Q Real-Time PCR Instrument
Figure Legend Snippet: Limit of Detection of LabTurbo TM AIO COVID-19 RNA Testing Kit for N1 and E Using the Rotor-Gene-Q Real-Time PCR Instrument

Techniques Used: Real-time Polymerase Chain Reaction

Cross-Reaction of the  LabTurbo  TM AIO COVID-19 RNA Testing Assay with Known Respiratory Viruses in Clinical Samples or Cell Supernatants
Figure Legend Snippet: Cross-Reaction of the LabTurbo TM AIO COVID-19 RNA Testing Assay with Known Respiratory Viruses in Clinical Samples or Cell Supernatants

Techniques Used:

Correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Rotor-Gene-Q real-time PCR instrument. ( A ) SARS-CoV-2 N1 versus RdRp screening results. ( B ) SARS-CoV-2 E screening results; correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Roche LightCycler96 instrument. ( C ) Shows SARS-CoV-2 N1 versus RdRp gene results. ( D ) Shows SARS-CoV-2 E gene results.
Figure Legend Snippet: Correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Rotor-Gene-Q real-time PCR instrument. ( A ) SARS-CoV-2 N1 versus RdRp screening results. ( B ) SARS-CoV-2 E screening results; correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Roche LightCycler96 instrument. ( C ) Shows SARS-CoV-2 N1 versus RdRp gene results. ( D ) Shows SARS-CoV-2 E gene results.

Techniques Used: Real-time Polymerase Chain Reaction

Related Articles

Virus:

Article Title: Adenovirus infection associated with central nervous system dysfunction in children.
Article Snippet: Background: Adenovirus is a common pathogen in the pediatric population.. No reports systemically evaluated central nervous system (CNS) dysfunction associated with adenovirus.. Objective: To describe the detailed clinical features of adenovirus-associated CNS dysfunction in children.

Article Title: Clinical Characteristics and Risk Factors for Seizures Associated With Norovirus Gastroenteritis in Childhood.
Article Snippet: Norovirus has become increasingly recognized as causing viral gastroenteritis in children.. Few data are available on the characteristics of children admitted to pediatric emergency departments with norovirus gastroenteritis and accompanying seizures.. Our aim in this study was to describe the clinical features of, and risk factors for, seizures accompanying norovirus gastroenteritis.

Article Title: Clinical features of radiologically confirmed pneumonia due to adenovirus in children.
Article Snippet: Background: Clinical features of radiologically confirmed pneumonia due to adenovirus in children have not been comprehensively evaluated.. Objective: To describe the detailed clinical features of radiologically confirmed adenovirus-associated pneumonia in children.. Study design: Of 3298 children with a throat virus culture positive for adenovirus treated at a universityaffiliated hospital, from January 2000 to June 2008, in northern Taiwan, 80 hospitalized children (2.4%) with radiologically confirmed pneumonia were identified.



Similar Products

94
LabTurbo Biotech labturbo virus mini kit
Labturbo Virus Mini Kit, supplied by LabTurbo Biotech, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labturbo+virus+mini+kit/LabTurbo+Viral+DNA%2BRNA+Mini+Kit/10__1039_slash_d5sd00231a-86-9-9
Average 94 stars, based on 1 article reviews
labturbo virus mini kit - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

90
Taigen Bioscience labturbo virus mini kit (cat. no. lvn480-300)
Limit of Detection of <t> LabTurbo </t> TM AIO COVID-19 RNA Testing Kit for N1 and E Using the Rotor-Gene-Q Real-Time PCR Instrument
Labturbo Virus Mini Kit (Cat. No. Lvn480 300), supplied by Taigen Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labturbo+virus+mini+kit/labturbo+virus+mini+kit++cat++no++lvn480+300+/pmc08882663-110-29-44
Average 90 stars, based on 1 article reviews
labturbo virus mini kit (cat. no. lvn480-300) - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

94
LabTurbo Biotech virus combo kit 24c lvx480 1000
Isolation method characteristics
Virus Combo Kit 24c Lvx480 1000, supplied by LabTurbo Biotech, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labturbo+virus+mini+kit/LabTurbo+Viral+DNA%2BRNA+Mini+Kit/pmc07788686-245-63-61
Average 94 stars, based on 1 article reviews
virus combo kit 24c lvx480 1000 - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

94
LabTurbo Biotech na isolation kit idxtract mag virus combo kit 24clvx4801000 nextprep mag cf dna isolation kit type bead based bead based column bead based sample
Isolation method characteristics
Na Isolation Kit Idxtract Mag Virus Combo Kit 24clvx4801000 Nextprep Mag Cf Dna Isolation Kit Type Bead Based Bead Based Column Bead Based Sample, supplied by LabTurbo Biotech, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labturbo+virus+mini+kit/LabTurbo+Viral+DNA%2BRNA+Mini+Kit/ppr0220364-304-33-21
Average 94 stars, based on 1 article reviews
na isolation kit idxtract mag virus combo kit 24clvx4801000 nextprep mag cf dna isolation kit type bead based bead based column bead based sample - by Bioz Stars, 2026-11
94/100 stars
  Buy from Supplier

90
Taigen Bioscience labturbo virus mini kit
Isolation method characteristics
Labturbo Virus Mini Kit, supplied by Taigen Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labturbo+virus+mini+kit/labturbo+496+standard+system/pm28482763-23-14-18
Average 90 stars, based on 1 article reviews
labturbo virus mini kit - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Taigen Bioscience labturbo virus mini kit labturbo 48 compact system
Isolation method characteristics
Labturbo Virus Mini Kit Labturbo 48 Compact System, supplied by Taigen Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/labturbo+virus+mini+kit/labturbo+496+standard+system/pmc05061319-110-32-36
Average 90 stars, based on 1 article reviews
labturbo virus mini kit labturbo 48 compact system - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Limit of Detection of  LabTurbo  TM AIO COVID-19 RNA Testing Kit for N1 and E Using the Rotor-Gene-Q Real-Time PCR Instrument

Journal: Infection and Drug Resistance

Article Title: Clinical Comparative Evaluation of the LabTurbo TM AIO ® Reverse Transcription-Polymerase Chain Reaction and World Health Organization-Recommended Assays for the Detection of Emerging SARS-CoV-2 Variants of Concern

doi: 10.2147/IDR.S349669

Figure Lengend Snippet: Limit of Detection of LabTurbo TM AIO COVID-19 RNA Testing Kit for N1 and E Using the Rotor-Gene-Q Real-Time PCR Instrument

Article Snippet: Total viral nucleic acid was extracted from 300 µL of each nasopharyngeal swab in a universal transport medium and eluted in a final volume of 60 µL using the LabTurbo Virus Mini Kit (Cat. No. LVN480-300) and an automated LabTurbo 48 Compact extraction system (Taigen Bioscience Corp., Taipei, Taiwan) according to the manufacturer’s instructions.

Techniques: Real-time Polymerase Chain Reaction

Cross-Reaction of the  LabTurbo  TM AIO COVID-19 RNA Testing Assay with Known Respiratory Viruses in Clinical Samples or Cell Supernatants

Journal: Infection and Drug Resistance

Article Title: Clinical Comparative Evaluation of the LabTurbo TM AIO ® Reverse Transcription-Polymerase Chain Reaction and World Health Organization-Recommended Assays for the Detection of Emerging SARS-CoV-2 Variants of Concern

doi: 10.2147/IDR.S349669

Figure Lengend Snippet: Cross-Reaction of the LabTurbo TM AIO COVID-19 RNA Testing Assay with Known Respiratory Viruses in Clinical Samples or Cell Supernatants

Article Snippet: Total viral nucleic acid was extracted from 300 µL of each nasopharyngeal swab in a universal transport medium and eluted in a final volume of 60 µL using the LabTurbo Virus Mini Kit (Cat. No. LVN480-300) and an automated LabTurbo 48 Compact extraction system (Taigen Bioscience Corp., Taipei, Taiwan) according to the manufacturer’s instructions.

Techniques:

Correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Rotor-Gene-Q real-time PCR instrument. ( A ) SARS-CoV-2 N1 versus RdRp screening results. ( B ) SARS-CoV-2 E screening results; correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Roche LightCycler96 instrument. ( C ) Shows SARS-CoV-2 N1 versus RdRp gene results. ( D ) Shows SARS-CoV-2 E gene results.

Journal: Infection and Drug Resistance

Article Title: Clinical Comparative Evaluation of the LabTurbo TM AIO ® Reverse Transcription-Polymerase Chain Reaction and World Health Organization-Recommended Assays for the Detection of Emerging SARS-CoV-2 Variants of Concern

doi: 10.2147/IDR.S349669

Figure Lengend Snippet: Correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Rotor-Gene-Q real-time PCR instrument. ( A ) SARS-CoV-2 N1 versus RdRp screening results. ( B ) SARS-CoV-2 E screening results; correlation between results obtained using LabTurbo TM AIO COVID-19 RNA testing assay and WHO-recommended assay with the Roche LightCycler96 instrument. ( C ) Shows SARS-CoV-2 N1 versus RdRp gene results. ( D ) Shows SARS-CoV-2 E gene results.

Article Snippet: Total viral nucleic acid was extracted from 300 µL of each nasopharyngeal swab in a universal transport medium and eluted in a final volume of 60 µL using the LabTurbo Virus Mini Kit (Cat. No. LVN480-300) and an automated LabTurbo 48 Compact extraction system (Taigen Bioscience Corp., Taipei, Taiwan) according to the manufacturer’s instructions.

Techniques: Real-time Polymerase Chain Reaction

Isolation method characteristics

Journal: Journal of Translational Medicine

Article Title: Qualitative and quantitative comparison of cell-free DNA and cell-free fetal DNA isolation by four (semi-)automated extraction methods: impact in two clinical applications: chimerism quantification and noninvasive prenatal diagnosis

doi: 10.1186/s12967-020-02671-8

Figure Lengend Snippet: Isolation method characteristics

Article Snippet: Four extraction methods were studied using their respective kit, 3 with the magnetic bead system and 1 with the silica membrane system: for magnetic beads isolation, the MagNA Pure 24 (Roche®) using MagNA Pure 24 Total NA Isolation Kit, the Chemagic 360 using NextPrep-Mag cfDNA isolation kit (Perkin Elmer®) and the IDEAL using IDXTRACT-MAG kit (IDSolution®); for silica membrane system, the LABTurbo using Virus combo kit 24C-LVX480-1000 (Taigen®).

Techniques: Isolation, Virus, DNA Extraction, Incubation